Inquiry For Liaison Service
Sector abcEducation And Research InstituteTender Value 14 Crore
LocationRajasthan - India Ref.No35656630
Closing Date07 - Aug - 2019
Supply of angioplasty items - radial introducer sheath 5fr. compatible with 6 fr guiding catheter - us fda approved standard length, pack must include 18 g, 6-7.5 cm long puncture needle, 0.035 or 0.038 inch guide wire compatible, with haemostatic valve to prevent back leak and air aspiration, integral side port with attached 3-way stopcock, with suture eye for securing sheath, kink resistant , with dilator-hub lock mechanism to prevent its back-out during insertion, with smooth and resistance free insertion, ", "radial introducer sheath 5fr. compatible with 6 fr guiding catheter - ce approved •standard length, pack must include 18 g, 6-7.5 cm long puncture needle, 0.035 or 0.038 inch guide wire compatible, with haemostatic valve to prevent back leak and air aspiration, integral side port with attached 3-way stopcock, with suture eye for securing sheath, kink resistant , with dilator-hub lock mechanism to prevent its back-out during insertion, with smooth and resistance free insertion, ", "radial introducer sheath 5fr. compatible with 6 fr guiding catheter - dcga approved •standard length, pack must include 18 g, 6-7.5 cm long puncture needle, 0.035 or 0.038 inch guide wire compatible, with haemostatic valve to prevent back leak and air aspiration, integral side port with attached 3-way stopcock, with suture eye for securing sheath, kink resistant , with dilator-hub lock mechanism to prevent its back-out during insertion, with smooth and resistance free insertion, ", "introducer sheath with puncture needle for adults (size 4 fr.- 9fr.) (standard length) us fda approved, sizes 4 french/5 french/ 6 french/ 7 french/ 8 french/ 9 french., 10-11 cm long, pack must include 18 g, 6-7.5 cm long puncture needle, 0.035 or 0.038 inch guide wire compatible, with haemostatic valve to prevent back leak and air aspiration, integral side port with attached 3-way stopcock, with suture eye for securing sheath, kink resistant , with dilator-hub lock mechanism to prevent its back-out during insertion, with smooth and resistance free insertion, ", "introducer sheath with puncture needle for adults (size 4 fr.- 9fr.) (standard length) ce approved, sizes 4 french/5 french/ 6 french/ 7 french/ 8 french/ 9 french., 10-11 cm long, pack must include 18 g, 6-7.5 cm long puncture needle, 0.035 or 0.038 inch guide wire compatible, with haemostatic valve to prevent back leak and air aspiration, integral side port with attached 3-way stopcock, with suture eye for securing sheath, kink resistant , with dilator-hub lock mechanism to prevent its back-out during insertion, with smooth and resistance free insertion", "introducer sheath with puncture needle for adults (size 4 fr.- 9fr.)(standard length) dcgi approved, sizes 4 french/5 french/ 6 french/ 7 french/ 8 french/ 9 french., 10-11 cm long, pack must include 18 g, 6-7.5 cm long puncture needle, 0.035 or 0.038 inch guide wire compatible, with haemostatic valve to prevent back leak and air aspiration, integral side port with attached 3-way stopcock, with suture eye for securing sheath, kink resistant , with dilator-hub lock mechanism to prevent its back-out during insertion, with smooth and resistance free insertion", "intoducer femoral sheath for adults (size 5 fr. – 11 fr.) specifically 10cm long(standard length) us fda approved, 5 fr. – 11 fr., 10 cm long, 0.035 or 0.038 inch guide wire compatible, with crosscut haemostatic valve to prevent back leak and air aspiration, integral side port with attached 3-way stopcock, m coat ( Special hydrophilic coating ), kink resistant , with dilator-hub lock mechanism to prevent its back-out during insertion, with smooth and resistance free insertion, ", "intoducer sheath for adults (size 10 fr. – 11 fr.)(standard length) ce approved, 10 fr. – 11 fr., 10-11 cm long, 0.035 or 0.038 inch guide wire compatible, with haemostatic valve to prevent back leak and air aspiration, integral side port with attached 3-way stopcock, with suture eye for securing sheath, kink resistant , with dilator-hub lock mechanism to prevent its back-out during insertion, with smooth and resistance free insertion, ", "intoducer sheath for adults 10 cm long (size 5 fr. – 11 fr.)(standard length) dcgi approved, 10 fr. – 11 fr., 10 cm long, 0.035 or 0.038 inch guide wire compatible, with haemostatic valve to prevent back leak and air aspiration, integral side port with attached 3-way stopcock, with suture eye for securing sheath, kink resistant , with dilator-hub lock mechanism to prevent its back-out during insertion, with smooth and resistance free insertion, ", "radial glidesheath introducer sheath with outer diameter one fr size under. ( 6 fr sheath with outer dia of 5 fr) us fda approved, sizes 5 french/ 6 french/ 7 french/ 8 french/ 9 french., sheath should be between 20-30 cm long, 0.035 or 0.038 inch guide wire compatible, with haemostatic valve to prevent back leak and air aspiration, i
If you are a new user, then please register, it's Free and then fill the form below.

If you are registered with us, just fill the form below, we will get back to you shortly.


All fileds marked with '*' are compulsary.
Email Id : *
Comments: *
 Login/Register
Members/Visitors Login to continue
 Email Id:
 Password:


 Forgot Password?
 Tenders by Industry
Skip Navigation Links.
Expand Chemicals TendersChemicals Tenders
more  »
Tenders by Ownership
Central Government/Public Sector Tenders
Co-operatives Tenders
Corporations/ Associations/ Others Tenders
Education & Research Institutes Tenders
Joint Sector Tenders
Non classified Tenders
Private Sector Tenders
Research Institutes Tenders
State Government Tenders
Trust Tenders
 Tenders by State in India
Andhra Pradesh Tenders
Delhi Tenders
Gujarat Tenders
Madhya Pradesh Tenders
Maharashtra Tenders
Rajasthan Tenders
Tamil Nadu Tenders
Uttar Pradesh Tenders
West Bengal Tenders
more  »